Service manual
09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
67
6. Press the Online button, set value is displayed.
7. Set the previously noted resistance value of the print head using the Feed
and Cut buttons.
8. Press the Online button to confirm the set value.
9. Press the Prog. button to return to the display OFFLINE 0 JOBS.
Temp. reduction
AP4.4 AP5.4 AP7.t
Reduction in the print head temperature
The parameter
SYSTEM PARAMETER > Temperature reduct. allows the power supply
to be reduced in the event of an increase in the print head temperature, there-
by ensuring an evenly good print image.
xxx% Setting range: 0 to 100%; Unit interval: 5%
The following setting alternatives are available:
y 0%: No temperature reduction.
y xx%: Up to xx% temperature reduction with a hot print head.
y Default setting: 20%.
P For further information refer to the user manual, topic section „Advanced
Application“, chapter „Printing with Termperature Compensation“
Thin line emphas
AP4.4 AP5.4
¯ Only in production mode
Thin line emphasis. Print emphasis for thin lines in order to get a better print
result.
On (Default) Print emphasis for thin lines is switched on.
Thin lines in the printout, which run crossways to the printing direction, are
printed approx. 1.5 times wider. This may have the effect, that small white
patches are closed with color (e.g. in the „e“ with very small fonts).
Off Print emphasis for thin lines is switched off.
Voltage offset
AP4.4 AP5.4 AP7.t
The voltage offset increases the head voltage and therefore the head tem-
perature which e.g. was set by Easy Plug command (HV).
xx% Setting range: 0 to 20%; Unit interval: 1%
Default setting: 0%