Service manual

09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
59
RFID Option
AP5.4
Disabled RFID-Option is not activated (RFID = Radio Frequency Identification).
¯ The RFID reader is connected to Com1 or Com2 internally, what means,
that it does not have to be plugged into the external serial interface
connector.
Serial Com1 The RFID reader is connected to Com1.
¯ This setting option is only visible, if no other option is activated at Com1.
Serial Com3 The RFID reader is connected to Com3.
¯ This setting option is only visible, if no other option is activated at Com3.
StandAlone Input
AP4.4 AP5.4 AP7.t
Defines an interface for data input in standalone mode.
¯ Interfaces are only selectable, if installed and not used by another
function (e. g. as data interface). If
INTERFACE PARA > EASYPLUGINTERPR >
Interface = „Automatic“
, all interfaces besides Com3 are blanked out.
None No data input via interface.
Serial Com1 Com1 is applied for data input in standalone mode.
Serial Com2 Com2 is applied for data input in standalone mode.
Serial Com3 Com3 is applied for data input in standalone mode.
TCP/IP socket TCP/IP socket is applied for data input in standalone mode.