Service manual
09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
58
WLAN signal lev.
AP5.4 AP7.t
¯ Only with plugged-in WLAN CF-card
Shows the WLAN average signal level in percent. This value suits for optimiz-
ing the location of the printer or access point to get the best network connec-
tion.
x% Signal level in %
P Detailed information about using the WLAN feature: read the user manual,
topic section Advanced Applications .
> OPTIONS
Remote Display
AP4.4 AP5.4 AP7.t
Parameter only for development use. Enables controlling the operation panel
via serial interface, e.g. with a PC.
¯ This parameter has nothing to do with the optional available remote
display, which is connected to a separate outlet.
P For details about installing the remote display option, see service manual of
the printer, topic section „Service Mechanics“, chapter „Assembling accesso-
ries“.
Disabled Remote display is not activated.
Serial Com1 The Remote display is connected to Com1.
¯ This setting option is only visible, if no other option is activated at Com1.
Serial Com2 The Remote display is connected to Com2.
¯ This setting option is only visible, if no other option is activated at Com2.