Service manual
09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
47
Stop bits
AP4.4 AP5.4 AP7.t
¯ With mounted and connected I/O board only.
P See parameter Stop bits on page 45.
Data synch.
AP4.4 AP5.4 AP7.t
¯ With mounted and connected I/O board only.
P See parameter Data synch. on page 46.
Serial Port Mode
AP4.4 AP5.4 AP7.t
¯ With mounted and connected I/O board only.
Setting of the serial interface type.
RS232 Sets Com2 to RS 232.
Data synchronisation may be done by hardware (RTS/CTS) or by software
(XON/XOFF). Maximum cable length is 15m.
RS422 Sets Com2 to RS 422.
RS 422 is a 4 wire point to point connection, suitable for only one device.
Receiver and driver of the printer are always enabled. Data synchronization
is only possible by software (XON/XOFF). Maximum cable length is 1 km with
twisted telecommunication cable.
RS485 Sets Com2 to RS 485.
RS 485 is a 2 or 4 wire bus system for up to 30 devices. The printer´s receiver
is always enabled, the printer´s driver is only enabled, if the printer sends
data to the host. Data synchronization is only possible by software (XON/
XOFF). Maximum cable length is 1km with twisted telecommunication cable.
Frame error
AP4.4 AP5.4 AP7.t
¯ With mounted and connected I/O board only.
P See parameter Frame error on page 46.