Service manual
09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
44
Printer ID No.
AP4.4 AP5.4 AP7.t
Printer identification number
Determines the identification number of the printer. In such a way, the printer
can be addressed by the Easy Plug command #!An (n=printer ID).
The use of ID numbers is in particular reasonable for data transfer by RS422/
485 interface, if several printers are connected by one data line. Each of the
connected printers then only incorporates the data mapped to him by #!An
command.
xx Setting range: 0 to 31; Unit interval: 1
Spooler size
AP4.4 AP5.4 AP7.t
The memory capacity of the printer buffer can be set according to the require-
ments of each customer.
xxx Kbyte Setting ranges:
– 64-xx Gen. 3: 16 to 2048KBytes
– Other devices: 16 to 256 KBytes
Unit interval: 16 KBytes; default setting: 64kBytes
¯ CAUTION! - All data present in the printer buffer is deleted when altering
the spooler size!
The maximum print format is influenced by the spooler size if no plug-in card
is used for memory expansion.
Offline mode
AP4.4 AP5.4 AP7.t
Interf. disabled Easy-Plug commands are not accepted, while the machine is in offline mode
(default setting).
Interf. enabled Easy-Plug commands are accepted in offline mode.
Interface delay
AP4.4 AP5.4 AP7.t
After switching from online to offline mode, the printer interface is deactivat-
ed. This parameter offers a setable delay time before deactivating the inter-
face.
xxxxms Setting range: 0-1000; Unit interval: 100; Default setting: 0