Service manual

09/09 Rev. 5.03-01 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 4.4 – AP 5.4 – AP 7.t
110
Com2 commun. test
AP5.4 AP7.t
¯ AP 5.4/AP 7.t: Only with installed I/O-board.
After calling this parameter, Com2 puts out all data which are received by the
set Easy Plug port.
P See parameter Interface on page 43.
If this parameter is set to RS232, data can also be sent in reverse direction
(that is, reception by Com2, output by Com1).
Com2 port test
AP5.4 AP7.t
¯ AP 5.4/AP 7.t: Only with installed I/O-board.
Starts a selftest of the Com2 port.
¯ Only works with RS 232.
¯ Pins 2/3 and 7/8 at the interface have to be connected (use a plug with
shunted pins)!
During the selftest, data transfer and handshake are tested. The test ends
with one of the following display messages:
Printtest
AP4.4 AP5.4 AP7.t
General printtest, prints line by line the set printer type and the firmware ver-
sion. Material settings (Material type, length, width) are considered.
Stop the printtest by pressing the Online button.
Com2 port test
Test failed
An error has occured while testing the interface.
Com2 port test
Test O.K.
Interface test successfully terminated.