Parallel connection
The parallel data transfer is done bidirectionally in the Nibble Mode. The
transfer test requires an aid program which is available to service engineers.
Receive test
AP4.4 AP5.4 AP7.t
Serial connection
Assumption is a serial data line between PC and printer; the parameter
INTERF.PARAM. > Interface must be set on RS232 or RS485.
1. Start the MS-DOS-window (using Windows).
2. Set the interface to the values adjusted at the printer by means of MS-DOS
command MODE:
Example of printer settings:
– Baud rate: 19200
– No. of data bits: 8
– Parity: none
– Stop Bits: 1
– Data synch.: RTS/CTS
DOS-Command: mode com2 19200 8 n 1
(if com2 is the serial port)
3. Press the Online-key to start Receive test.
4. Send any file to the printer (Condition: com2 = Printer port; anyfile.txt = any
file ):
copy anyfile.txt com2 (add /b for binary files)
The following shows up on the printer display:
xxxxxx is the size of the sent file in bytes. This value is being counted up dur-
ing the test. The test is complete if the file size does not vary any more. If the
bytes announced at the printer match the size visible in the MS-DOS window,
transfer was successful. Otherwise, transmission errors occurred.
Parallel connection
Assumption is a parallel data line between PC and printer; the parameter
INTERF.PARAM. > Interface must be set up on Centronics. Proceed as follows:
1. Run Receive test. To this call the parameter
SERVICE FUNCTION > Receive test and
press the Online-key.
Receive test
0 Bytes
Receive test
xxxxx Bytes
Receive test
0 Bytes