Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
99
Head strobes
AP5.4 AP5.6
Shows the counted head strobes, which are a measure for the service life of
the printhead. A strobe is counted for each line in which at least one dot ist
printed. Maximum value: 4 billions.
Head temperature
AP5.4 AP5.6
Shows the current printhead temperature in °C.
Foil diameter
AP5.4 AP5.6
Shows the calculated foil diameter: A measurement routine calculates the ac-
tual ribbon roll diameter with an exactness of 7.5%.
The parameter
SYSTEM PARAMETER > Foil end warning can be used to set a critical
foil roll diameter. If the foil roll diameter equals this value, a message appears
on the printer display.
P See parameter Foil end warning on page 68.
Dispensing cycl.
(Dispensing cycles)
AP5.4 AP5.6
¯ AP 5.4/5.6: Dispenser version only.
Shows the number of dispensed labels.
Operation time
AP5.4 AP5.6
Shows the elapsed time since the last switch-on of the machine.