Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
75
Min. rew. current
AP5.4 AP5.6
¯ Only in production mode.
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
Minimal rewinder current
This parameter influences the rewinder current with 25 mm rewinder dia-
meter (min. rewinder diameter).
XXX% Setting range: 50-200%; Default setting: 100%
Precondition for the setting in percent:
Parameter
DISPENSER PARA > Current mode = Table values (see above).
XXX Setting range: 0-750; Default setting: 100;
Precondition for the setting in absolute values:
Parameter
DISPENSER PARA > Current mode = Absolute values (see above).
Max. rew. current
AP5.4 AP5.6
¯ Only in production mode.
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
Maximum rewinder current
This parameter influences the rewinder current with 120 mm rewinder dia-
meter (max. rewinder diameter).
XXX% Setting range: 50-200%; Default setting: 100%
Precondition for the setting in percent:
Parameter
DISPENSER PARA > Current mode = Table values (see above).
XXX Setting range: 0-750; Default setting: 250;
Precondition for the setting in absolute values:
Parameter
DISPENSER PARA > Current mode = Absolute values (see above).
The two parameter values Min. rew. current and Max. rew. current are used
by the motor output stage to calculate all other current values for diameters
lying in between.
Problem Solution
The label web runs too loose around the dispensing edge
during printer operation.
The label roll is wound up too loose.
Increase the setting
The label web runs too tight around the dispensing edge
during printer operation.
The label roll is wound up too tight.
Decrease the setting
[6] Cases, in which the setting of the minimal rewinder current has to be corrected.