Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
74
Start error stop
AP5.4 AP5.6
Function for operation with product sensor.
Determines the reaction of the machine on a product start error. A product
start error occurs in the following cases:
y If a further start signal arrives, before the current label is completely printed.
y With mounted I/O board only: If a reprint is requested, before the first label
after powering on is printed.
y If a start signal arrives and no printjob is loaded.
If a product start error occurs, the machine stops and displays the appropriate
status message. If an I/O board is installed, the following output signals are
activated (set low):
y ERROR\
y MACHINE STATUS\
On Start errors are worked up (the machine stops!) (default setting)
Off Start errors are being ignored.
Product length
AP5.4 AP5.6
Function for operation with product sensor.
If this function is activated, the printer ignores all start signals until the product
has passed the dispensing edge.
0.0mm Setting range: [0.0…1999.9] mm; Default setting.: 0,0
Current mode
AP5.4 AP5.6
¯ Only in production mode.
¯ Only if SYSTEM PARAMETER > Periph. device = „Dispenser“.
The setting of this parameter influences the impact of the paramters Min rew.
current and Max rew. current.
Table values Display of the automatically calculated motor current chart PWM values
(in %). On the base of this setting, the printer calculates the motor current val-
ues for Min rew. current and Max rew. current out of print speed and material
width. The calculated values appear as default 100%.
Absolute values With this setting, the printer doesn´t calculate and doesn´t adapt to material
width and print speed. The set values for Min rew. current and Max rew.
current are given to the output stage without a modification. The valueas ap-
pear as absolute values.
¯ The setting "Absolute values" should only be applied by qualified
personnell!