Service manual

Table Of Contents
03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
69
End print mode
AP5.4 AP5.6
¯ Only with an I/O board mounted.
¯ Not available in batch mode.
Concerns the output signal PRINT_END at the I/O board signal interface.
Determines the signal response after printing of a label.
Mode0 inactve No print end signal.
Mode1 high level Low, if the print module is just printing a label, otherwise high.
The output is also deactivated (= low) as long as labels are fed with “Feed
Button” or
“Feed Signal”.
Mode2 low level High, if the print module is just printing a label, otherwise low.
The output is also deactivated (= high) as long as labels are fed with “Feed
Button” or “Feed Signal”.
Mode3 low pulse (Default setting) Low for 20 ms after printing and dispensing a label.
The output is also activated (= low) after a label is fed with “Feed Button” or
“Feed Signal”.
Mode4 high pulse High for 20 ms after printing and dispensing a label.
The output is also activated (= high) after a label is fed with “Feed Button” or
“Feed Signal”.