Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
69
End print mode
AP5.4 AP5.6
¯ Only with an I/O board mounted.
¯ Not available in batch mode.
Concerns the output signal PRINT_END at the I/O board signal interface.
Determines the signal response after printing of a label.
Mode0 inactve No print end signal.
Mode1 high level Low, if the print module is just printing a label, otherwise high.
The output is also deactivated (= low) as long as labels are fed with “Feed
Button” or
“Feed Signal”.
Mode2 low level High, if the print module is just printing a label, otherwise low.
The output is also deactivated (= high) as long as labels are fed with “Feed
Button” or “Feed Signal”.
Mode3 low pulse (Default setting) Low for 20 ms after printing and dispensing a label.
The output is also activated (= low) after a label is fed with “Feed Button” or
“Feed Signal”.
Mode4 high pulse High for 20 ms after printing and dispensing a label.
The output is also activated (= high) after a label is fed with “Feed Button” or
“Feed Signal”.