Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
54
Character filter
AP5.4 AP5.6
Character >= 20Hex Filter function is activated. Characters smaller than 20H are filtered out of the
data flow.
All character Filter function is deactivated. Characters smaller than 20H are treated as nor-
mal characters.
Light sens. type
AP5.4 AP5.6
Light sensor type
The optional reflex photoelectric switch for labels with reflecting length mark-
ings, or the normal factory-fitted photoelectric switch for labels with transpar-
ent or register gaps (self-adhesive labels), must be defined according to the
application.
Short label opt. Activates the optional short label sensor.
¯ Appears only in AP 5.4 printers which are equipped with the short label
sensor.
Reflex Reflex photoelectric switch (for reflecting markings)
Punched Transparent photoelectric switch (for gaps)
Head-sensor dist.
AP5.4 AP5.6
¯ Parameter appears only in production mode or if a value > 0 is set.
Printhead-sensor distance
Special function for setting non-standard punch sensors. Such sensors can
be applied in special application devices ("Nistan"). The value x is the dis-
tance between thermal edge and punch sensor in millimeters.
x mm Setting range: 0 to 400 mm
¯ A „non standard sensor“ must be installed and connected instead of the
regular punch sensor.
¯ 0 = disabled (the regular punch sensor is used).