Service manual

Table Of Contents
03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
49
1. Press the Esc button. The cursor jumps to the first character.
2. Press the Cut- or Feed button until the wanted character appears.
Acknowledge by pressing the Online button.
3. Type in the next character.
4. Acknowledge the new password by pressing the Online button.
¯ Alternatively, the password can be typed in using a keyboard, or via the
web server.
Time client
AP5.4 AP5.6
Loads the current time from a time server.
Disabled The time client is switched off.
Enabled The time client is switched on. The time is loaded with the frequency set un-
der
Sync. interval from a time server with the IP address Time server IP.
With the time client service, the current date and time can be obtained
from a time server using RFC868 time protocol on UDP port 37. For
this purpose, a time server IP address needs to be given. Date and
time are initially requested at start up an optional in a setable update interval
during operation time. It is also stored in the internal real time clock. There is
no time offset or daylight saving hour, so the server time must exactly match
the local time of the printer.
Time server IP
AP5.4 AP5.6
IP address of the time server.
¯ Only appears if INTERFACE PARA > NETWORK PARAM. > Time client =
„Enabled“.
xxx.xxx.xxx.xxx Enter the IP address following the xxx.xxx.xxx.xxx schema.
Setting range for each xxx value: [0…255].
Sync. Interval
AP5.4 AP5.6
Determines the frequency for time requests.
¯ Only appears if INTERFACE PARA > NETWORK PARAM. > Time client =
„Enabled“.
xxxx Setting range: [0…9999] s; Default setting: 3600 s.