Service manual

Table Of Contents
03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
38
INTERFACE PARA
Interface parameter
> EASYPLUGINTERPR
Interface
AP5.4 AP5.6
Interface type
This parameter sets the interface, by which the printer will receive data.
Serial Com1 Serial interface Com1.
P Selection of the type of serial interface is done with parameter INTERF. PARAM >
EASYPLUGINTERPR > Serial Port Mode
.
Only for Ethernet interface (10/100 Base T):
TCP/IP Socket Print data can be sent to the printer via a TCP/IP socket
LPD Server Print data can be sent to the printer via the LPR/LPD-protocol
USB USB 1.1 interface
Serial Com3 Serial interface Com3.
¯ Only with optional I/O board mounted.
Automatic All interfaces are enabled to receive data, but not simultaneously.
¯ Don´t send data to more than one interface at a time.
¯ Except are interfaces, which are being used by an option (e.g. OLV).
Spooler mode
AP5.4 AP5.6
The operating mode of the spooler determines whether print series are proc-
essed individually, or whether the spooler can receive print data when print-
ing several series.
Single print job Single print series mode (the interface can only receive data after printing the
required number of labels of a single series)
Mult. print jobs Multiple print series mode (the interface can receive data while the series is
being printed)