Service manual
Table Of Contents
- General Information
- Operating the parameter menu
- Overview Parameter Menus
- Alphabetical Parameter List
- PRINT INFO
- PRINT PARAMETERS
- INTERFACE PARA
- SYSTEM PARAMETERS
- Foil end warning
- Foil warn stop
- Print Interpret.
- Character sets
- Character filter
- Light sens. type
- Head-sensor dist.
- Sens. punch-LS
- Foil mode
- Turn-on mode
- Error reprint
- EasyPlug error
- Single job mode
- Head resistance
- Temp. reduction
- Thin line emphas
- Voltage offset
- Miss. label tol.
- Gap detect mode
- Periph. device
- Singlestartquant
- External signal
- Start print mode
- Print contrast
- Ram disk size
- Font downl. area
- Free store size
- Print info mode
- Reprint function
- Language
- Keyboard
- Access authoriz.
- Realtime clock
- I/O BOARD
- DISPENSER PARA
- REWINDER PARA
- MLI PARAMETERS
- SPECIAL FUNCTION
- SERVICE FUNCTION
- SERVICE DATA

03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP 5.4 Gen II – AP 5.6
28
Material type
AP5.4 AP5.6
Definition of the materials used. A distinction is made between reel material
and gapped material (hole gaps, self-adhesive material with register gaps).
The detected gap position corresponds to the start of the label.
¯ The value is overwritten by the appropriate Easy Plug command when
sending label formats.
Endless If material is to be used without gaps.
Punched If material is to be used with gaps (default setting).
Material length
AP5.4 AP5.6
The material length (label length) is the distance between the gaps, meas-
ured from the front edge (beginning) of a label to the front edge of the next
label.
¯ The value is overwritten by the appropriate Easy Plug command when
sending label formats.
xxx mm Setting range: 5 mm to "max. length entry"; Unit interval: 0.1 mm
Default setting: 100 mm
Maximum length entry: dependent on the print head width and memory con-
figuration.
Material width
AP5.4 AP5.6
Zero position of the left border. If the printer is working in line-printer mode,
alterations can be made in millimetre units.
xxx mm Setting range: "min. width" to "max. width"; Unit interval: 0.1 mm
Default setting: 100 mm
y Min. width: dependent on the printer type
y Max. width: dependent on print head width and memory configuration.
P For detailed material width information, refer to topic section „Specifications“.