#PC2512/1 #G Rewinder Motor : Generation 2
#PC2501/0 #G Current mode : Table values
#PC2502/100 #G Min rew. current : 100
#PC2503/250 #G Max rew. current : 250
#PC2504/170 #G Min rew. current : 170 %
#PC2505/170 #G Max rew. current : 170 %
#PC2506/0 #G Start rew. curr. : 0 %
#PC2507/30 #G Start cur. len. : 30 mm
#PC2508/95 #G Pullback current : 95
#PC2509/50 #G Back diameter : 50 mm
#PC2510/0 #G Break current : 0
#PC2511/120 #G Break diameter : 120 mm
#G-------------------------------------------------------------------
---
#G Dispenser Interface
#G-------------------------------------------------------------------
---
#PC3001/0 #G Interface type : USI interface
#PC3002/0.0 #G Start delay : 0.0 mm
#PC3003/0 #G Start print mode : Pulse falling
#PC3004/0 #G End print mode : Mode 0
#PC3005/0 #G Reprint signal : Disabled
#PC3006/1 #G Ribbon signal : Enabled
#PC3007/0 #G Material signal : Disabled
#PC3013/60.0 #G Diam. mat. end : 60.0 mm
#PC3008/0 #G Feed input : Standard
#PC3012/0 #G Pause input : Standard
#PC3009/0 #G Start error stop : Off
#PC3010/1 #G Internal inputs : Enabled
#PC3011/0 #G Apply mode : After start sig.
#G-------------------------------------------------------------------
---
#G Textile Parameter Menu
#G-------------------------------------------------------------------
---
#PC3301/1 #G Changelabel Mode : Always at jobend
#PC3302/1 #G Changelab Print : With print
#PC3303/10 #G Changelab Length : + 10 mm
#PC3304/1 #G Label Eject Mode : Yes, at job end
#PC3305/0 #G Head lift autom. : after 0 labels
#G-------------------------------------------------------------------
---
#G Applicator Parameter Menu
#G-------------------------------------------------------------------
---
#PC3101/0 #G Applicator type : LTP - LTPV
#PC3102/0 #G Apply mode : After start sig.
#PC3110/2 #G Start print mode : Pulse rising
#PC3103/0 #G Start error stop : Off
#PC3104/0 #G APSF sensor res. : 0 pulses/m
#PC3105/0.0 #G Start delay : 0.0 mm
#PC3106/1 #G Dwell time : 1 ms
#PC3107/1 #G Blow on time : 1 ms
#PC3108/0 #G Restart delay : 0 ms
#PC3109/2000 #G Position timeout : 2000 ms
#PC3212/0 #G Start error stop : Off