User manual

03/10 Rev. 5.04-02 USER MANUAL Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x – PM 3000
29
Storing and transferring parameter settings
Recommendations
Suitable printers: All printers listed in the headline, apart from the AP 4.4
(which has no card slot)
Firmware:
Application cases
Sometimes, it will be necessary to reinstall all parameter settings of a printer
at a time or to transfer the settings to another printer. In those cases, the op-
erator can save time, money and nerves by loading all the parameter settings
completely. The following cases are possible:
After a printer is being serviced, it is supposed to get the same settings as
before.
The parameter settings of one printer are supposed to be transferred to an-
other printer of the same type.
Several printers of the same type should be provided with the same set-
tings.
It is adviseable to read out and to store the parameter settings completely, to
be able to restore them later. To do so, there are two ways:
Easy-Plug Reading out via the interface by means of appropriate Easy-Plug commands.
This requires sound knowledge of the command language Easy-Plug and is
not further discussed here.
Further information: refer to the Easy-Plug manual, topic section Description
of commands , commands #!PG and #PC.
CF card Storing the parameter settings on CF card in a text file („setup file“) (see de-
scription below).
Printer Feature Firmware version
64-xx, DPM, PEM, ALX 92x Gen. 2 3.40
64-xx, DPM, PEM, ALX 92x Gen. 3 5.02
PM 3000 -- 5.03n
AP 5.4, AP 7.t -- 3.00
AP 5.4 Gen II, AP 5.6 MLK 7.34
[Tab. 22] Minimum firmware requirement if it is to store or transfer parameter settings.