Technical data

82
7APPENDIX
7.1 FACTORY SETTINGS
ALS
380
In the case of a memory error: – The message W__2 or E_12 appears on the
operator panel.
– All databanks are deleted.
– The settings of the machine are reset to fac-
tory settings [79].
Function Value Explanation
VELO 0500 Labelling speed: 50.0 m/min
STOD 0000 Distance between dispensing edge and label's leading edge: 0.0 mm
POS 0500 Distance between leading edge of product and label: 50.0 mm
POS 2 0000 Multiple labelling: Distance between the leading edges of the first and second label:
0mm
POS 3 0000 Multiple labelling: Distance between the leading edges of the second and third label:
0mm
VERT 0100 Dispensing speed = conveyor belt speed
CONT 0035 Sensitivity of the label stop sensor
E–SS 0064 Distance between label stop sensor and dispensing edge: 64 mm
LPIT 1000 Label distance: 100.0 mm
PRDL AUTO Product length = LPIT
P_S_ LEDG Product sensor: Triggered by leading edge
S_S_ LEDG Label stop sensor: Triggered by leading edge
MLAB 0000 Machine stops as soon as a product is not labelled.
PDT 0000 Label stop = Printer start
PDWT 0000 Printer dwell time: 0.0 s
EGRA 0600 APSF compensation factor for RPM transmitter with 0.166 mm/pulse
TMOD OFF Tandem operation off
7 APPENDIX
7.1 FACTORY SETTINGS