Technical data

79
6OPERATIONAL MALFUNCTIONS
6.2 ERROR MESSAGES
ALS
380
E__2 Label stop sensor does not detect
the labels.
Ribbon of labels does not run through the slot in the photoe-
lectric sensor:
Check the ribbon guide at the label stop sensor.
Label roll empty or more than 3 labels missing:
Replace label roll as required.
Pressure roller not closed:
Swing back the pressure roller dispenser head and return
it to its position pressing against the roller. The pressure
roller clicks neatly into its operating position.
Insufficient labelling speed:
The product pulls the label off of the base material.
Synchronise the labelling speed and product speed (VE-
LO function).
Other options:
Manually adjust the sensitivity of the label stop
sensor (CONT).
Check the label stop position (STOD).
Check the label distance setting (LPIT).
Check to see whether the feed motor at the dis-
penser head is running.
E__3 The photoelectric sensor in the loop
space does not detect the loop for-
mation and the label stop sensor
does not detect the labels.
Refer to E__1 and E__2; First check the loop formation.
E__4 Rewind unit problems Label roll empty:
Replace label roll.
Label ribbon torn:
Rethread the label ribbon at the rewind unit.
Rewinding motor runs too slowly or is defective:
Setting or adjustment by servicingtechnician is re-
quired; refer to the Service Guide
E__5 Photoelectric sensor in the loop
space does not detect the loop for-
mation and problem with the rewind-
ing unit.
Refer to E__1 and E__4.
E__6 Label stop sensor does not detect
the labels and problem with the re-
wind unit.
Label ribbon torn:
Rethread the label ribbon at the rewind unit.
Message Description Possible causes and remedies