Technical data
50
4OPERATION
4.3 PRODUCT DATABANKS
ALS
380
4.3.3 Create/save product databank
Prerequisites
CAUTION!
Erroneous settings can lead to production
setbacks, damage to the machine and sys-
tem!
– Only appropriately qualified and author-
ised personnel may create product data-
banks.
– Settings in the following functions are updated:
1) Setting the EGRA is required when operating the automatic dispensing
speed adjustment APSF
Saving the product databank
In the extended menu:
➔ Call up the SAVE function.
➔ Select the desired product databank using the
NEXT or PRIOR key.
– 11 product databanks are available.
➔ Using the ENTER key, save the current settings in
the selected product databank.
➔ Exit the extended menu using QUIT.
If the selected product databank already contains
data:
– The question YES? appears on the display.
➔ Confirm the query by pressing the ENTER key to
overwrite the selected product databank with the
new data.
Should the product databank not be overwritten:
➔ Press the NEXT key until QUIT appears on the dis-
play.
➔ Press the ENTER key.
– The selected product databank is closed without be-
ing saved.
➔ Select another product databank to save the current
settings.
Documenting product databanks
➔ Document the contents of the product databanks in
a table. Use the example copy in the appendix.
–POS –MLAB
–POS2 –PDT
–POS3 –PDWT
– VELO – EGRA
1)
– STOD – VERT
– CONT – APPL
– E–SS – APT1
– LPIT – APT2
– PRDL – APT3
– P_S_ – APT4
–S_S_