Technical data

45
4OPERATION
4.2 SETTING AND MONITORING
ALS
380
4.2.5 Automatic material
initialisation (INIT)
Also refer to chapter Activation and shut-down.
In the standard menu, press the NEXT or PRIOR
key until INIT [48] is displayed on the operator pan-
el.
Call the INIT function by pressing the ENTER key.
Press and hold the FEED key.
The message AUTO appears on the operator panel.
The machine slowly starts up and dispenses a label.
Release the FEED key once a label gap has passed
the photoelectric sensor [49A] at the dispenser
head.
If the initialisation was successful:
"ON" appears on the operator panel.
When the FEED key is pressed, a label is dis-
pensed.
If the initialisation was unsuccessful:
The message FAIL appears on the operator panel.
Initiate the INIT function again.
or:
Manually initialise the material employing
qualified calibration technicians.
If the FEED key is not pressed down when INIT
is displayed on the operator panel, but only
lightly actuated:
The values for the label distance setting and
the label stop sensor will be deleted provided
these values are stored in the control unit.
Continual feed at maximum speed is trig-
gered.
The continual feed only stops after a mal-
function occurs.
To prevent operational malfunctions, switch
off the machine at the main switch as soon
as possible.
[48] INIT display on the operator panel
[49] Backing material with a label under the label stop sensor (A)
A