Technical data

95
7APPENDIX
7.1 FACTORY SETTINGS
ALS
350
450
In the case of a memory error:
The message W__2 or E_12 appears on the
operator panel.
All databanks are deleted.
The settings of the machine are reset to fac-
tory settings [93].
Function Value Explanation
VELO 0500 Labelling speed: 50.0 m/min
STOD 0000 Distance between dispensing edge and label's leading edge: 0.0 mm
POS 0500 Distance between leading edge of product and label: 50.0 mm
POS2 0000 Multi-labeling: Distance between the leading edges of the first and second la-
bel: 0,0 mm
POS3 0000 Multi-labeling: Distance between the leading edges of the second and third
label: 0,0 mm
VERT 0100 dispensing speed = conveyor belt speed
CONT 0035 Sensitivity of the label stop sensor
LPIT 1000 Label distance = 100.0 mm
E-SS 0016 Distance between label stop sensor and dispensing edge: 16 mm
PRDL AUTO Product length = LPIT
P_S_ LEDG Product sensor: Triggered by leading edge
S_S_ LEDG Label stop sensor: Triggered by leading edge
MLAB 0000 Machine stops as soon as one product is not labelled
PDT 0000 Label stop = Printer start
PDWT 0000 Printer dwell time: 0.0 s
EGRA 0600 Compensation factor for RPM transmitter for automatic speed adjustment
TMOD OFF Tandem operation deactivated
APPL DIR Applicator mode deactivated
APT1 0001 EP cylinder dwell time: 1ms
APT2 0001 Blowing time: 1ms
APT3 0000 Delay time: 0ms
APT4 0001 Fine tuning of dwell time: 1ms
MDIR Turning direction of all motors for right-hand version
OMOD ON Machine goes into online mode (operation-ready) after switch-on
TAND 0000 Distance between product-sensors during tandem operation: 0.0 mm
SLEW 0055 Dispense speed during missing label compensation: 55 m/min
COMP ON Automatic label compensation deactivated
7 APPENDIX
7.1 FACTORY SETTINGS