Technical data

84
4OPERATION
4.6 APPLICATOR (OPTIONAL)
ALS
350
450
EP cylinder dwell time (APT1)
Dwell time for the EP cylinder
In the extended menu:
£ Call up the APT1 function.
£ Set the desired value.
Settings are possible in 1 ms steps:
1 ... 7500 ms
£ Confirm the setting using the ENTER key and exit
the function.
Blowing time (APT2)
When using a blowing applicator:
Dwell time for blowing the label on the product
In the extended menu:
£ Call up the APT2 function.
£ Set the desired value.
Settings are possible in 1 ms steps:
1 ... 7500 ms
£ Confirm the setting using the ENTER key and exit
the function.
Delay time (APT3)
When using an EP applicator:
Delay of the signal air blow.
The signal controls the air blow which blows the la-
bel onto the underside of the applicator. The value
for APT3 is the delay between the start of label dis-
pensing and activation of the air blow.
In the extended menu:
£ Call up the APT3 function.
£ Set the desired value.
Settings are possible in 1 ms steps:
1 ... 5000 ms
£ Confirm the setting using the ENTER key and exit
the function.