Technical data
77
4OPERATION
4.4 SETTINGS IN THE EXTENDED MENU
ALS
350
450
4.4.12 Number of unlabelled products
(MLAB)
If products do not get labelled, the operator receives
the warning message W_0 at the operator panel. If too
many products in a row do not get labelled, the machine
stops. The error message E_11 appears at the opera-
tor panel. Using the MLAB function, you can determine
how many products in a row are allowed to be unla-
belled before the machine stops.
Example [84]:
MLAB is set to value 2. The machine stops after three
products in a row are not labelled. The error message
E__11 appears on the operator panel.
In the extended menu:
£ Call up the MLAB function.
£ Set the desired value.
– Possible settings: 0 ... 10 products
£ Confirm the setting using the ENTER key and exit
the MLAB function.
4.4.13 Electronic transmission ratio
of the RPM transmitter (EGRA)
– Compensation factor for RPM transmitter when op-
erating with automatic dispensing speed adjustment
– Refer to Chapter Automatic dispensing speed
(APSF), Page 80.
[84] Three products in a row were not labelled.