Technical data

75
4OPERATION
4.4 SETTINGS IN THE EXTENDED MENU
ALS
350
450
4.4.9 Product length (PRDL)
A start signal can be prematurely triggered by the
shape of the product or reflective surfaces. In such a
case, the product length must be manually set.
Example [81]:
If the product [D] reaches the product sensor [C], a start
signal is sent and the machine dispenses a label. The
recesses in the product trigger additional start signals;
without the PRDL function, the product would be la-
belled several times. With the product length [A] set in
the PRDL function, the machine ignores all start signals
until the product has passed the dispenser head.
In the extended menu:
£ Call up the PRDL function.
£ Set the product length.
Settings are possible in 1 mm steps:
Minimum: 5 mm
Maximum: 999 mm
£ Confirm the value using the ENTER key and exit the
function.
To set the product length the same as the label dis-
tance:
£ Set the value for PRDL to less than 5.
The message AUTO appears on the operator panel.
The control system automatically sets the value for
PRDL to the value of the label distance (LPIT).
[81] A Product length
B Label
C Product sensor
D Product with recesses (arrows)
A
D
C
B