Technical data
59
4OPERATION
4.2 SETTING AND MONITORING
ALS
350
450
4.2.5 Automatic material initiali-
sation (INIT)
Also refer to chapter Activation and shut-down.
£ In the standard menu, press the NEXT or PRIOR key
until INIT [62] is displayed on the operator panel.
£ Call the INIT function by pressing the ENTER key.
£ Press and hold the FEED key.
– The message AUTO appears on the operator panel.
– The machine slowly starts up and dispenses a label.
£ Release the FEED key once a label gap [63 arrow]
has passed the photoelectric sensor [63A] at the
dispenser head.
If the initialisation was successful:
– „ON“ appears on the operator panel.
– When the FEED key is pressed, a label is dis-
pensed.
If the initialisation was unsuccessful:
– The message FAIL appears on the operator panel.
£ Initiate the INIT function again
or:
£Manually initialise the material employing
qualified calibration technicians.
If the FEED key is not pressed down when INIT
is displayed on the operator panel, but only
lightly actuated:
– The values for the label distance setting and
the label stop sensor will be deleted provided
these values are stored in the control unit.
– Continual feed at maximum speed is trig-
gered.
– The continual feed only stops after a mal-
function occurs.
£To prevent operational malfunctions, switch
off the machine at the main switch as soon
as possible.
[62] INIT display on the operator panel
[63] Initialise the label material
A