4.2.3 Dispensing speed (VELO)
As a rule, the labelling speed must correspond to the
product speed. Depending on the operating conditions,
the labelling speed can also be set somewhat higher in
unique cases.
Prerequisites:
The label stop position (STOD) is correctly set.
£ In the standard menu, press the NEXT [57A] or
PRIOR [57B] key until VELO [58] is displayed on
the operator panel.
£ Call up the VELO function by pressing the
ENTER [57C] key.
The current speed is displayed on the operator pan-
el in m/min.
£ Change the labelling speed using the NEXT or
PRIOR key.
Settings are possible in steps of 0.1 m/min:
Minimum: 0.5 m/min
Maximum: 55 m/min
£ Confirm the desired value using the ENTER key and
exit the VELO function.
Test the setting:
£ Remove the pressure roller unit at the dispensing
edge.
£ Start the system and only label one product.
The labelling speed is too low if the product pulls the
label away from the backing material.
The labelling speed is too high if the label on the
product has folds in it.
Automatic dispensing speed (optional)
If the automatic dispensing speed (APSF) is activated:
Only display of the current speed using the VELO
function.
Manual setting of the dispensing speed is not possi-
ble.
For further information on the APSF function, see
chapter 4 OperationAutomatic dispensing speed
(APSF) Page 80.