713 Receiving failure or illegal command. Call Technical Support.
714 Receiving failure or undefined command. Call Technical Support.
730 A memory allocation error occurred during initialization.
750 Printhead is overheated. Turn off the printer to let the printhead cool. If the error
persists, call Technical Support.
751 Printer did not sense a black mark when expected. The supply may be jammed. For
errors 751-753, check the
¨ supply tracking
¨ supply marks
¨ black mark sensor position
¨ supply roll for binding.
If the error continues to appear, change the supply
752 Printer sensed a mark in the wrong place.
753 Printer sensed a mark that is too long.
754 Printer has a ribbon problem. Check the ribbon for a jam or remove any slack by
turning the take-up reel clockwise. Load a new ribbon.
755 Printhead is open. Close the printhead before continuing. If the error persists, call
Technical Support.
756 The printer is out of supplies. Load supplies.
757 Load supplies. The calibrated supply length differs by plus or minus .25 inches from
the format. Press the FEED button to print on the current supply or load new supply.
758 Check supply. Either the supply is not seen, or the on-demand sensor is broken
(purchase optional). Check for a label jam. Clear the supply path or reload supplies.
This error may occur if you remove a label too quickly in on-demand mode. The
printer does not recalibrate after this error.
762 Low battery. Recharge the battery.
763
Waiting to dispense label. Press the FEED button.
766 Backfeed error. There is a problem with the backfeed or overfeed distance.
767 Incorrect AD value. Call Technical Support.
768
Printhead has more than 10 bad dots within the format area or is not connected.
Make sure the printhead is connected.
769 The printhead is not receiving enough volts. Call Technical Support.
770 The print motor is not ready. Call Technical Support.
771 The format specified by the application was not found. Reload your application and
format, and try again. If the problem continues, call Technical Support.
781 The voltage is too low. Call Technical Support.
DIAGNOSTICS AND ERRORS 8-13