Specifications

38
Control Panel Operation Users Manual Model 686 / 686 HT
CALIBRATE SENSORS
P
R
E
S
S
E
N
T
E
R
T
O
C
A
L
I B
R
A
T
E
S
E
N
S
O
R
S
This screen follows the "PRINT HEAD SETUP" screen.
Pressing ENTER will take the user to the "CALIBRATE SENSORS" screens.
Pressing the MODE / Down Arrow key will take the user to the "LIFE COUNTS /
VERSIONS" screen. Pressing the EXIT / Up Arrow key will take the user back to
the "HOME" screen.
H
O
L
E
/ S
L
O
T
I N
S
E
N
S
O
R
V
A
L
U
E
:
0
0
0
N
E
W
V
A
L
U
E
:
0
0
0
This is the first screen under "CALIBRATE SENSORS". Place the stock hole / slot
sense mark under the sensor. Slowly move the stock under sensor until the NEW
VALUE reading is its smallest value then press ‘Enter’.
Pressing the MODE / Down Arrow key will take the user to the "HOLE / SLOT
NOT IN SENSOR" screen. Pressing the EXIT / Up Arrow key will take the user
back to the "HOME" screen.
H
O
L
E
/ S
L
O
T
N
O
T
I N
S
E
N
S
O
R
V
A
L
U
E
:
0
0
0
N
E
W
V
A
L
U
E
:
0
0
0
This screen follows the "HOLE / SLOT IN SENSOR" screen. Place the stock under
the sensor so that it blocks the sensor and when NEW VALUE is at its largest value
press ‘Enter’.
Pressing the MODE / Down Arrow key will take the user to the "TOP REFL OVER
MARK" screen. Pressing the EXIT / Up Arrow key will take the user back to the
"HOME" screen.
T
O
P
R
E
F
L
O
V
E
R
M
A
R
K
V
A
L
U
E
:
0
0
0
N
E
W
V
A
L
U
E
:
0
0
0
This screen follows the "HOLE / SLOT NOT IN SENSOR" screen. Place the stock
under the sensor so that the reflective mark is under the sensor and when NEW
VALUE is at is largest value press ‘Enter’.
Pressing the MODE / Down Arrow key will take the user to the "TOP REFL NOT
OVER MARK" screen. Pressing the EXIT / Up Arrow key will take the user back to
the "HOME" screen.