Specifications
Users Manual Model 686 / 686 HT Printer Setup •
••
• 11
Fuse Configuration
The main fuse(s) on the AVERY DENNISON 686 / 686 HT are located inside the
AC entry. The entry has a fuse drawer that holds the fuse(s) and selects the
appropriate line voltage. If the voltage in the window DOES NOT match the AC
line amplitude intended to be supplied to the printer, DO NOT plug the power cord
in. Reconfigure as follows:
1) Using a flat blade screwdriver, open the AC entry by lifting the tab just above
the voltage indicator window.
AC Entry
2) Remove the red fuse drawer.
3) Remove all fuses and the fuse jumper if it is present.
4) Insert into the fuse drawer the correct number and style of fuse(s) and fuse jumper
for your application.
Configuration Number One: Line voltage within the range of
(See 115VAC Fuse Placement) 90 - 132VAC @ 50 - 60Hz
1) Install one 990689 – 6.25A 250V Fast Acting 1/4 x 1 1/4"
2) Install one Fuse Jumper