User manual
165
- In Camera section, select and click on the camera number (01 to 16) in Motion Detected and
Video Loss to set the condition for the system to alarm.
- In Missing and Suspicious Object Detected, click the camera number (01 to 16) and select
the certain object on the screen (right click on camera number for detailed setting)), and when
the certain object is missing or doubtful, the system will alarm. (see also Chapter 5.9.12
) In
Scene Change, when the camera has been moved, the system will alarm, too.
- In Voice Detection, click the camera number (01 to 16) to the system to alarm when detect
the abnormal voice.
5. In (4) Sensor, select and click on the sensor number (use W and X to select the sensor) to set
the condition for the system to alarm. If the sensor normal status is high, set the sensor condition
to low.
- Enable/disable the Abnormal Event check box, to set the condition of the event for system to
alarm.
Normal Reboot: when the DVR system reboot without abnormal condition, the system will
send out the alarm message.
Abnormal Reboot: when the DVR system reboot in irregular condition, the system will
send out the alarm message.
Recording is switched off: when the recording has been stopped, the system will send
out the alarm message.
Network is switched off: when the network connection of DVR system is lost, the system
will send out the alarm message.
Hard Disk failed: when the hard disk can’t work normally, the system will send out the
alarm message.
Temperature: set a temperature limited of system for system to alarm. When DVR system
temperature is over the temperature limited, the system will send out the alarm.
Illegal Entry: any objects move between selected regions which user has set up in
Object Counting section (see also Chapter 5.2.1)
, the system will send out the alarm.
Select the entry (object moves from region 1 to 2 or from region 2 to 1) and camera for
system alarm detection.
- Enable/disable the POS Keyword check box, to scan the data from the POS if it matches the
keyword (see also Chapter 5.9.10
).
- Enable/disable the Alarm Message check box, to active with external alarm message by
your own program. For the detail configuration, please contact the local reseller.
6. In (5) Alarm Reset, click the camera number (use W and X to select the alarm) to set the reset
condition of alarm. Once alarm is reset, all alarm action will stop at the moment. If the sensor
normal status is high, set the sensor condition to low.
7. In (6) Action, you may now set the alarm action for the system to perform when the alarm
condition is activated.
- Launch E-Map
Display mini Emap screen.
- TV Out
Switch to only display the video on TV from where the alarm is activated.