User manual
9
2.6 Sensor and Relay pinhole allocation on NX8000 series
i
NXU8000 series needs to purchase the E-I/O box for I/O connection.
The signal from the sensor (i.e., infrared sensors, smoke detectors, proximity sensors, door sensors,
etc.) is being transmitted to the I/O card, and this triggers the system to respond and send signal to
relay device (i.e., alarm, telephone etc).
2019181716151413121110987654321
Pin # Definition Pin # Definition
1 Sensor input signal 1+ 11 Relay Normal Close 1
2 Sensor output signal 1-(GND) 12 Relay Common 2
3 Sensor input signal 2+ 13 Relay Normal Open 2
4 Sensor output signal 2-(GND) 14 Relay Normal Close 2
5 Sensor input signal 3+ 15 Relay Common 3
6 Sensor output signal 3-(GND) 16 Relay Normal Open 3
7 Sensor input signal 4+ 17 Relay Normal Close 3
8 Sensor output signal 4-(GND) 18 Relay Common 4
9 Relay Common 1 19 Relay Normal Open 4
10 Relay Normal Open 1 20 Relay Normal Close 4