User manual
92
In (5) Alarm Reset, click the camera number (use W and X to select the alarm) to set the reset
condition of alarm. Once alarm is reset, all alarm action will stop at the moment. If the sensor
normal status is high, set the sensor condition to low.
To set sensor status of IP camera, click IP Camera Sensor. In IP Camera Alarm Setting windows,
click High/Low to set sensor status.
- Alarm Reset Time: Set a time for the alarm auto reset. When an alarm happen such as
motion detected and video loss, the alarm will reset at the alarm reset time.
In (6) Action, you may now set the alarm action for the system to perform when the alarm
condition is activated.
- Launch E-Map
Display mini Emap screen.
- TV Out
i
Alarm TV Out doesn’t support on NXU8000 series.
Switch to only display the video on TV from where the alarm is activated or selected camera.
a. Select the camera from drop down list to specify which camera video to be displayed on
TV when the alarm is triggered.
~ Alarm Camera: when a channel has an alarm occurred, and then, the channel video
that has an alarm occurred will be displayed on TV.