User manual

41
low .
- Continue trigger duration: Set a time period for system to send out the alarm when sensor
has been trigger and stay in the same status for a period.
- Enable/disable the Abnormal Event check box, to set the condition of the event for system to
alarm.
Normal Reboot: when the DVR system reboot without abnormal condition, the system will
send out the alarm message.
Abnormal Reboot: when the DVR system reboot in irregular condition, the system will
send out the alarm message.
Recording is switched off: when the recording has been stopped, the system will send
out the alarm message.
Network is switched off: when the network connection of DVR system is lost, the system
will send out the alarm message.
Hard Disk failed: when the hard disk can’t work normally, the system will send out the
alarm message.
Temperature: set a temperature limited of system for system to alarm. When DVR system
temperature is over the temperature limited, the system will send out the alarm.
i
Temperature setting only supports on NV6000 Express card.
Illegal Entry: any objects move between selected regions which user has set up in
Object Counting section (see also Chapter 5.2.1 of NV user’s manual), the system will
send out the alarm. Select the entry (object moves from region 1 to 2 or from region 2 to 1)
and camera for system alarm detection.
- Enable/disable the POS Keyword check box, to scan the data from the POS if it matches the
keyword (see also Chapter 5.9.10
).
- Enable/disable the Alarm Message check box, to active with external alarm message by your
own program. For the detail configuration, please contact the local reseller.
- Enable/disable the Alarm Button check box, to active manual alarm function (see also
Chapter 4.3#(17) of NV user’s manual). To define alarm message of manually alarm trigger.
Click alarm button and select the alarm button # and fill in the description of alarm button.
6. In (5) Alarm Reset, click the camera number (use W and X to select the alarm) to set the reset
condition of alarm. Once alarm is reset, all alarm action will stop at the moment. If the sensor
normal status is high, set the sensor condition to low.
- Alarm Reset Time: Set a time for the alarm auto reset. When an alarm happen such as motion
detected and video loss, the alarm will reset at the alarm reset time.
7. In (6) Action, you may now set the alarm action for the system to perform when the alarm
condition is activated.
- Launch E-Map
Display mini Emap screen.
- TV Out
Switch to only display the video on TV from where the alarm is activated.
a. Select the camera from drop down list to specify which camera video to be displayed on
TV when the alarm is triggered.
i. Alarm Camera: when a channel has an alarm occurred, and then, the channel video
that has an alarm occurred will be displayed on TV.
ii. Camera #(1~32): select the camera channel video that wants to be displayed on TV
when an alarm is activated.
b. Retrieve time: set the waiting duration before system switching back to original display
mode on TV automatically. If the retrieve time is un-mark, the alarm video will keep
displaying until user switch back to normal display mode manually. The retrieve time range
is 3~ 600 seconds.
- Enlarge Camera View
Switch to only display video in Preview/Advanced mode from where the alarm is activated.