User manual

122
- Start Recording
Record the video from the selected camera.
1. Beside the Start Recording check box, click Detail.
2. In the Alarm Recording Setting dialog box, select the
camera to enable/disable video recording. Enable All to
select all cameras.
3. In the Frame Rate selection, select As Setting to
record the number of frames based on the Recording
Setting.
4. In the Start Record prior text box, mark and set the
number in second for the program to begin recording
after the alarm has been trigger. The time range is 1~10
seconds.
5. In the Stop Record after text box, mark and set the number in second for the program to continue
recording after the alarm has ended. The time range is 1~999 seconds. If user doesn’t mark and set
the time, the alarm recording will continue recording until alarm is reset.
6. Click OK to accept the new settings and Cancel to exit without saving.
- PTZ preset point
Position the PTZ camera based on the preset point setting. Beside
the PTZ preset point check box, click Detail. In the Trigger PTZ
Preset Setting dialog box, select the PTZ camera number then select
the Enable check box. Select the position of the PTZ camera when
the alarm is activated and ended. For the PTZ camera end point, user
can also select on preset position or Auto Pan between preset
position groups.
- Send to CMS (Central Management System)
Enable/disable the selected camera to send video to
CMS when the alarm is activated. Beside the Send to
CMS check box, click Detail. In the CMS Setting,
select the camera to enable/disable sending the video
to CMS. Enable All to select all cameras. Then, click
OK to accept the new settings and Cancel to exit
without saving.