This section describes remote operation of the SW HDMI switchers. Topics include:
Using Simple Instruction Set (SIS) Commands
Updating Firmware Using Firmware Loader
Using Simple Instruction Set (SIS) Commands
The SW HDMI can be remotely set up and controlled via Extron SIS commands that are
issued from a host computer or other device, such as a control system. SIS commands can
be issued via RS-232 from the computer serial port to the rear panel Remote port, or via
USB from the computer USB port to the front panel Config port. (See “Wiring for RS-232
Control” on page 7 or “Connecting to the USB Port” on page 8 to connect to these
ports.)
Host-to-switcher Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. You can enter these commands from
your computer using a communication software program such as Extron DataViewer or
HyperTerminal. When the switcher determines that a command is valid, it executes the
command and sends a response to the host device.
Most responses from the SW HDMI to the host computer end with a carriage return and
a line feed (CR/LF = ]), which signals the end of the response character string. A string is
one or more characters.
Switcher-initiated Messages
When a local event such as a front panel selection or a change in signal status takes place,
the switcher responds by sending a message to the host, indicating what selection was
entered. No response is required from the host.
The following switcher-initiated message is displayed:
(C) Copyright 20nn, Extron Electronics HDMI Switcher Series, Vn.nn,
60-641-nn
The switcher sends the copyright message when it first powers on. Vn.nn is the firmware
version number; 60-641-nn is the switcher part number.