Use and Care Manual
Test Report
No.: SHHL1909051579IF Date: NOV. 25, 2019 Page: 2 of 19
Test Conducted:
1. EN 16582-1:2015 Domestic swimming pools Part 1: General requirements including
safety and test methods
2. EN 16582-3:2015 Domestic swimming pools Part 3: Specific requirements including safety
and test methods for aboveground pools
Sample Size: 1 piece
Clause
Test Method / Requirement
Result
Rating
1.
EN 16582
-
1:2015
4. General requirements and test methods
4.1 General In use, installed according to the installation and
commissioning manual, the swimming pool shall meet the
requirements of this document.
If the pool structure includes any water system covered by the
prEN 16713 series, the EN 16582 series shall be read in
conjunction with the prEN 16713 series.
Assembled in accordance with the installation and
commissioning manual, the electrical installation of any
material related to the pool and its surrounding shall also
comply with the requirements of HD 60364-7-702 or valid
national requirements.
When a membrane is used as a watertight system, it is not
mandatory to have a minimum thickness, however any
relevant standards shall apply if they exist.
All manufacturers are required to carry out, either internally or
via a test laboratory, the tests mentioned in Clause 4 for each
new or revised material process.
/ Pass
4.2 Tolerance The indicated dimensions and measurements are given with
a tolerance of ± 3% (unless otherwise indicated).
Claim:
L x H:
3.0m x 76cm
Water depth:
68cm
Water body:
2.70m
Actual:
L x H:
3.0m x 75cm
Water depth:
67cm
Water body:
2.65
m
Pass
4.3 Water
leakage
Wherever possible, swimming pools should be built so that
they are watertight, as leakage and other water losses may
affect the building and surrounding properties.
The
maximum leakage is specified in Table 1.
Tightness
class: W0
Pass