VSI-Pro Cash Register Interface Operation Manual Version 12.
VSI-Pro IS YEAR 2000 FCC CE COMPLIANT CAUTION! RISK OF ELECTRICAL SHOCK! DO NOT OPEN! CAUTION! TO PREVENT ELECTRIC SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE! WARNING! THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS.
CONTENTS 1. INTRODUCTION ..................................................................... 4 2. FEATURES ................................................................................ 5 3. CONNECTION ......................................................................... 6 4. PROGRAMMING..................................................................... 9 4.1 FRONT CONTROL PANEL .................................................. 9 4.2 GETTING STARTED ...............................................
1. INTRODUCTION The Video Serial Interface (VSI-Pro) allows characters to be inserted into any video source via an RS-232 link. This allows computers, cash registers, ATM's and any RS-232 communicating device to display alphanumerics in the video picture of a CCTV system. Simple front panel push-buttons allow the user to interactively on-screen program this powerful device.
2. FEATURES • 45 Different Cash Register Selections. • Easy On-screen Menu driven Setup and Programming. • 24 Field Programmable Exceptions with Numeric Range. • Programmable Time-Stamp on Exception Output. • Universal or American Time/Date format. • 100 lines Exception History Buffer. • 16 Triggered Text associated with 16 alarms. • 2 built-in Programmable Alarm Outputs. • Alarm Input for Drawer Open, Safe Open, etc.
3. CONNECTION The VSI-Pro will overlay the characters on any input video source. The video input can be virtually any base band or composite video source. The VSI-Pro will accept NTSC, RS-170, RS-330, CCIR, PAL or SECAM video formats. The Video input to the VSI-Pro is a standard BNC connector, terminated at 75 [ohms]. NOTE: The input video level must be 1[V] Peak to Peak.
CONNECTION VIDEO OUT VIDEO IN FIGURE 1: VSI-Pro Connections Table 1 :Pin-out of the DB-9 connector on the VSI-Pro 80
CONNECTION 3.1 RS232 SERIAL INPUT The VSI-Pro accepts serial data via DB-9 female connector located on the rear of VSI-Pro. This Connector is similar to “AT” type computer RS232 serial ports and the pin out is identical. Table 1 shows the standard pin out for VSI-Pro RS-232 female connector.
4. PROGRAMMING The VSI-Pro is programmed by pressing and releasing specific combinations of the four front panel push-buttons. Via these four simple buttons, all of the powerful programming features of the Text Inserter are available. A video source and a monitor must be connected in order to see the programming menus. Figure 2: Four Front P annel Push Buttons of VSI-Pro 4.
PROGRAMMING Changing the Gray scale Down 1) 2) 3) 4) 5) Up Set Reset Press and hold the Down button Press and release the Reset button Release the Down button Press Down or Up to select the Gray scale When choice is made, press and release the Reset button Changing the Horizontal Position Down 1) 2) 3) 4) 5) Up Set Reset Press and hold the Up button Press and release the Reset button Release the Up button Press Down or Up to move the text block When choice is made, press and release the Reset but
PROGRAMMING 4.2 GETTING STARTED To access the main menu of the VSI-Pro, simultaneously hold down the “DOWN” & “UP” buttons and press & release the “RESET” button and then release the “DOWN” & “UP” buttons. This will take you to the main programming menu as appeared in the Figure 3. To navigate through this menu, simply use the “DOWN” & “UP” buttons to position the arrow in front of the desired function, then press “SET” to access that section.
PROGRAMMING 4.3.1 REGISTER SELECT To select a specific register place the arrow cursor in front of “REGISTER SELECT “ of the “MAIN MENU” and press and release “SET” button. The “REGISTER SELECT” will bring up a sub-menu consisting of registers shown in the Table 3. You can go to the next or previous page by placing the cursor in front of “NEXT” or “PREVIOUS “and then press and release “SET” button.
PROGRAMMING TABLE 3 : Continued REGISTERS MO DEL SPEC IAL C ABLE GILBARC O G- SITE X X GILBARC O TC R G/2 X G2 MO D SPEC IAL MO D GILBARC O TC R 15 (O LD) X SPEC IAL MO D IBM 3151 TERMIN AL X X IBM RDS X X MEM5 X X X MIC RELEC MASTER SERISE X X 9500 X X MIC RO PO S X X X MIC RO MAX X X X MIC RO S LO C AL VSS X MAX232 O R MO D 485 IDN N ETWO RK X X ISN N ETWO RK X X NCR 2113,3000 X N C R 2113 MO D N IXDO R BEETLE X X N O RAN D 12 0 0 X X PA
PROGRAMMING 4.3.2 SCREEN SETUP Place the arrow cursor in front of SCREEN SETUP and press and release “SET”. Screen set up menu will appears on the monitor as shown in Figure 4. . CHARACTER SIZE . BORDER/ GRAY SCALE . HORIZONTAL POS . VERTICAL POS . CLOCK . ONSCREEN TITLER . EXIT FIGURE 4: VSI-Pro screen set up menu Character Size To change the size of the characters on the screen, position the arrow cursor in front of “ CHARACTER SIZE” and press and release “SET”.
PROGRAMMING Horizontal Position To change the horizontal position of the inserted text on-screen, position the arrow in front of “HORIZONTAL POS” and press “SET”. Press the “UP” or “DOWN” buttons to move the text to the desired horizontal position. Vertical Position To change the vertical position of the inserted text on-screen, position the arrow in front of “VERTICAL POS” and press “SET”. Press the “UP” or “DOWN” buttons to move the text to the desired vertical position.
PROGRAMMING RESET TIME /DATE resets the clock to the default value. T/D the LOCKING turns time/date locking on/off. If the T/D Locking is turned on, make sure that the time format selected is the same as the registers time/date format. If the T/D LOCKING is turned on, the VSI-Pro will monitor the incoming data string. If it finds a valid time and date in one or two consecutive lines, it will set the clock to whatever time/date it finds.
PROGRAMMING Titler To change the status of the on-screen titler, position the arrow in front of “TITLER” and press “SET”. The arrow will start flashing. Select either “ON” or “OFF” by pressing “UP” or “DOWN” button. After making selection press and release “SET” button, this will return the arrow to the non-flashing mode.
PROGRAMMING Exit Place the arrow in front of the “EXIT” and press and release “SET” button to return to the main menu. 4.3.3 TEXT DISPLAY This menu will give you more control over the actual text block formatting and its appearance on the screen. To acess the menu position the arrow in front of “TEXT DISPLAY” and press and release “SET”. Sub-menu similar to the Figure 7 will be appear on the screen. . SCREEN BLANK . DISPLAY LINES . TRUNCATE . LINE COMPRESS . LEFT JUSTIFIED . SCROLL DELAY . DISPLAY .
PROGRAMMING NOTE: Choosing “NONE” means No Blanking. The VSI-Pro will display the last transaction until a new transaction is performed. Display Lines You have the choice of how many lines of text to display on-screen for register transactions. The choices are upto 9 lines. To change the “DISPLAY LINES” setting, place the arrow in front of DISPLAY LINES and press “SET”. The arrow will begin flashing. Now, by pressing the “UP” or “DOWN” buttons, you can cycle through the selections.
PROGRAMMING Line Compress NOTE: Set your Exceptions first, before enabling this feature. The VSI-Pro automatically compresses the spaces in a line first as it reaches 20 characters. With LINE COMPRESS “ON” the VSI-Pro will additionally remove multiple spaces and then vowels from the text to further compress the display as necessary. To make this selection, position the arrow in front of “LINE COMPRESS” and press and release “SET”; the arrow will start flashing.
PROGRAMMING The choices for “SCROLL DELAY” are either “ON” or “OFF”. To make this selection, position the arrow in front of “SCROLL DELAY” and press and release “SET”. The arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “UP” or “DOWN” buttons, then press and release “SET” when your choice is displayed. The arrow will stop flashing, and you can continue programming.
PROGRAMMING 4.3.4 COMMUNICATION This was discussed briefly in the section under “REGISTER SELECT” and will be fully explained here. When you choose your register type under the “REGISTER SELECT” menu, this automatically formats the VSI-Pro to the appropriate settings needed to communicate with your register. There may be times when you will need to amend these settings for a specific register. To access the “COMMUNICATIONS” menu, place the arrow in front of “COMMUNICATION” and press “SET”.
PROGRAMMING TX Baud Rate Choices: 28.8K AUTO, 150, 300, 600, 1200, 2400, 4800, 9600, 14.4K, 19.2K, This feature allows you to set the transmit baud rate to a separate device of a different baud rate than the connection to the cash register. When the register input baud rate is much higher than the output baud rate the VSI-Pro internal 28K buffer will hold the data until the printer is ready.
PROGRAMMING Hand Shake Choices ON, OFF Handshaking is an electrical signal that tells the Cash Register or Computer that the VSI-Pro is ready to receive data. This signal is called “CTS” or Clear to Send. When the VSI-Pro asserts this signal the transmitting device should not send more data. It is not be necessary to connect this signal from the Cash Register or Computer since the VSI-Pro does not require Handshaking and contains a very large 28K data buffer.
PROGRAMMING Exception Report Overview The Exception Report gives you the option to assign an on-screen flag, trigger an alarming device, or send data to another serial device on any questionable transaction that you have preprogrammed into the VSI-Pro. The VSI-Pro will allow programming of up to 24 separate exceptions.
PROGRAMMING Hard Alarm Output The VSI-Pro allows you to program exceptions to trigger external alarming devices such as Time-Lapse VCR’s, Quads, Enunciators, LED’s etc. Using the Alarm Output you can have your time-lapse VCR record only exceptions, or have an alarming Quad go to full screen on an exception, or even trigger a buzzer to alert you that an exception has occurred. PRINTER OUTPUT There may be situations where you do not want cashiers or other employees to know what triggers an exception.
PROGRAMMING Programming Your Exception Report From the main programming menu, place the arrow in front of “EXCEPTION REPORT” and press and release “SET”. This will take you to the Exception Reports' menu, which is shown in Figure 9. EXCEPTION HISTORY SET EXCEPTION OUTPUT ON TIME STAMP O F F EXIT Figure 9: Exception Report Sub Menu Exception History Selecting this item displays the following submenu as appeared in Figure 10.
PROGRAMMING on the screen, starting with the oldest exception in the buffer. Once in the exception displaying screen, pressing DOWN or UP keys scrolls to next screen. Press the SET button to return to main menu. Select OUTPUT EXCEPTIONS to have the buffered exceptions sent out for printing. Select CLEAR HISTORY to clear all the buffered exceptions and reset the TOTAL EXCEPTIONS Counter. Selecting ''EXIT' brings you back to the Exception Report main menu.
PROGRAMMING sequence through the choices. Make your selection and press and release “SET”. The arrow will stop flashing and you may continue to the next menu item. NOTE: Two Exception strings 23 and 24 are pre-programmed for beginning and ending transaction with DISPLAY OFF.
PROGRAMMING Output The “OUTPUT” controls the RS-232 data from the VSI-Pro. Typically this is sent to a remote Serial Printer to provide a hard copy of Exceptions with time and date on it. This data can also be sent out to a computer with appropriate software and give you the ability to analyze data. You could also use an auto answer modem and have the data sent to a central office or even to your home.
PROGRAMMING For example in Samaung ER-4715 register an assign Exception string “..” will flag all Void, Refund, Merchandise Return and Paid out to the monitor. You can also use wild card symbol “.” a centered dot on any data location. Example of this would be instead of assigning eight different exception string for dept 00 to dept07 you can assign only one exception string e.g. “dept . .”. That wild card exception string will handle exception for all eight departments.
PROGRAMMING the display off for that exception. In the Exception Strings enter the words “ WELCOME TO XYZ SUPER ”. Exactly as they appears on the screen, including spaces. ( Note: Only 20 characters are allowed in each exception string, including blank spaces ). OPERATOR The “OPERATOR” determines the behavior of the “RANGE”. Think of the OPERATOR in mathematical terms.
PROGRAMMING this character, use the “UP” or “DOWN” buttons to move between 0-9. To move to the next block, press and release the “SET” button. This will advance the active block to the next block immediately to the left . This is how you move through the “RANGE” field. While you are on an active block, pressing the “UP” and “SET” buttons simultaneously will return that block back to a blank, which is designated by a solid white box. You can follow this format to program your “RANGE”.
PROGRAMMING To turn Time Stamp “ON” or “OFF”, place the arrow cursor in front of Time Stamp and press and release “SET” button. After selecting a choice again press and release “SET” button , arrow will stop blinking and ready for your next command. Exit Place the cursor in front of Exit and press and release set button to exit out of Exceptions Report sub menu. Examples for Setting Exception EQUAL Suppose Exception #2 would be flag all $10 sales on Register Department 1.
PROGRAMMING In Range Suppose Exception #5 would flag all transactions between $50.00 & $100.00 on Department 3: Exception No. 3 Display O N Output ON or OFF (Depending on presence of serial printer). Exception String 3 ... Range 0049.99<->0099.99 Operator IN With this exception all sales between $50 and $100 dollars will be flagged. GREATER THAN This example will show you how to program an exception to flag all sales in department 5 greater than $100 dollars Exception No.
PROGRAMMING 4.3.6 ALARM OUTPUTS To access alarm output, place the arrow in front of “ALARM OUTPUTS” and press and release “SET”. You will be presented with the following sub-menu shown in Figure 12. ALARM NO. ALARM TRIG NORMAL STATE ALM DURATION FLAG TYPE FLAG DURATION RTS TRIGGERED TEXT EXIT Figure 12: Sub menu for Alarm Output The ALARM OUTPUTS menu controls not only the formatting of the external alarms, but also the formatting of the on-screen flags assigned to individual exceptions.
PROGRAMMING ALARM TRIG An ALARM TRIGGER is the source of activity programmed to activate a certain alarm. The Alarm Trigger tells the VSI-Pro what exception to use to trigger the alarming device or the on-screen flag. The choices are: Exceptions 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, & 24: (alarms when data is received that matches what you have set in these exception strings). Exceptions 1-12: set in Exception alarms 1-12.
PROGRAMMING NORMAL STATE There are two choices: NO (normally open) or NC (normal closed). These selections determine whether the alarm outputs will act as a normally open switch or a normally closed switch. To select the Normal State that you want to program, place the arrow in front of “NORMAL STATE” and press and release “SET”. The arrow will start flashing . By using the “DOWN” & “UP” buttons, toggle through and make your selection.
PROGRAMMING To make your selection place the arrow in front of “ FLAG TYPE” and press and release “SET”. The arrow will start flashing . By using the “DOWN” or “UP” buttons, toggle between the choices and make your selection.
PROGRAMMING Each Triggered Text can contain up to 40 printable ASCII data. If nonprintable data (control code) is included, each control code occupies 3 printable spaces. Therefore, only 13 control codes maximum can be programmed in one Triggered Text. To program the TRIGGERED TEXT, go to the ALARM OUTPUTS sub-menu. Select desired ALARM NO or RTS for external alarm. Then go to the TRIGGERED TEXT sub-menu this is same as what appeared in figure 13.
PROGRAMMING Set Triggered Text Place the arrow in front of Set Triggered Text and press and release “SET” button. You can enter 2 lines with 20 alpha numeric text on each line. To set the trigger text to output a “Control Character” you must first program the up-arrow “#“, and then two digits for the HEX code value. e.g. tp put ^A (HEX code 01H), program in #01. Press “UP” and “DOWN” at the same time to exit out of Set triggered text . This will save the trigger text to memory.
PROGRAMMING RECEIVE (RX) TEST TRANSMIT (TX) TEST RX/TX TEST BAUD RATE SCAN EXIT Figure 14: Port test 1 sub menu RECEIVE (RX) TEST The purpose of this test is to determine that if VSI-Pro receiving the data or not. To test that move the cursor in front of “RECEIVE (RX) TEST” Receiving data will be appear in three sperate lines, scrolling from right to left. First line is the actual ASCII data coming from the register while last two lines are HEX conversion of ASCII data.
PROGRAMMING RX/ TX TEST In the RX/ TX test VSI-Pro echo whatever it receives. To proceed with test, place the arrow in front of “RX/TX TEST” and press and release SET. Baud Rate Scan Baud Rate scan test can scan the baud rate of your register. To proceed with the test, place the arrow in front of baud rate scan and press and release “SET” button. Enter a transaction from the register, VSI-Pro will detect the baud rate and display it in front of RX Baud rate.
PROGRAMMING non RS 232 format data. Capture to memory This feature allow you to store the data in the internal memory of VSI-Pro. You can store up to 28 kilobytes of data in the internal memory of VSI-Pro. Power up the VSI-Pro 24 hour prior to down load data. That will provide VSI-Pro internal battery additional power to hold data in its memory. To start downloading place the arrow in-front of Capture to the memory and than press and release the “SET” button.
PROGRAMMING can use this demo data to configure exceptions and alarms to be fully functional for a complete customer demonstration. To access this demonstration, place the arrow in front of REGISTER DEMO and press and release “SET”. The demo will start after a few seconds. To exit this demo, press and release “RESET”. Version ID When selected display the version of software in use by the VSI-Pro. LOGO This demo displays the AVE logo cycling through several sizes.
PROGRAMMING 3 --------------2 2 --------------3 5---------------5 Figure 15: download data cable UP LOADS would be to have a system set up with two separate cameras and monitors and the programmed VSI-Pro with the down load data cable attached. The VSI-Pro programming data is stored internally in a battery backed 32K x 8 SRAM. This would allow you to program one VSI-Pro on site and bring the programmed VSI-Pro back to the shop or office and program additional VSI-Pros quickly.
PROGRAMMING CAMERA IN VIDEO OUT TO MONITOR Figure 16: Down Load Set Up Between VSI-Pro and VSI-Pro Now, by using the “UP” and “DOWN” buttons, you can move the display side to side on the screen. Move the text block as far to the left as you can and press “RESET” to exit. Now let’s move the display to the top of the screen. Hold down the “SET” button and press and release “RESET”, then release “SET”. Now the “UP” and “DOWN” buttons will move the display up and down on the screen.
PROGRAMMING Let’s bring up the PROGRAMMED VSI-Pro first. To do this, simultaneously press and hold “UP” and “DOWN” and press and release “RESET” , then release “UP” and “DOWN”. This will bring up the main menu and it should be on the left half of the screen. Now go to the other VSI-Pro and do the same thing. You should now have both programming menus side by side. NOTE: Depending on the size of the monitor you are using, these two menus may overlap, but should not be a problem.
PROGRAMMING data transfer will start and you will have a screen count down of the status that reads: Programmed UPLOADING VSI ...1 Unprogrammed DOWNLOADING VSI ...1 The count will end at 99. When this prompt clears the screen, the data transfer is complete. Press Reset to exit this menu on both VSI-Pro’s. Now go to the main programming menu of the previously unprogrammed VSI-Pro on the right side of the screen. Enter the EXCEPTIONS menu.
APPENDIX A PROBLEM SOLVING GUIDE No 1. 2. 3. 4. 5. data on screen. Press the reset button on Incorrect register selected Data cable is miswired. Data cable is too long or May be connected to the the VSI-Pro front panel. in the Register Select Menu. did not use shielded cable. wrong port. Problems With CR boards 1. Check that the board is seated properly in the register. 2. Check jumper settings on the CR board if applicable. 3.
PROBLEM SOLVING GUIDE Characters Jitter, Jump or Skew Note: The VSI requires 1V p-p +/- 20 percent, terminated @ 75 ohms. 1. Darken the gray scale of the characters. 2. Video Input level less than 1VP-P - use an amplifier to get the proper level. 3. Poor input sync signals - too many AC coupled amplifiers in the video input signal. 4. Noisy or poor quality video sourceReplace with better source. 5. Check for double termination. 6. Video level too high; VSI-Pro will clip video. 7.
PROBLEM SOLVING GUIDE My customer is changing registers; will the VSI they have work on the new register? This is a tricky one. We interface to over 400 different registers and as a result, there are several versions of software needed to work with all these different systems. The probability the VSI will work with a new system is relatively high, specially if its Version 11 based.
APPENDIX B Triports / Adaptors / Cables 53
TRIPORT AND ADAPTER CABLE Generic Cable: Dresser Wayne DB-9M DB-9M DB-9F DB 9 DB9(M) 3 2 5 5 Addressable VSI Note: Consult Factory PC COM 1,2,3,4 Note: Consult Factory Delta Sono Note: Consult Factory Dresser Wayne Cable: Dresser Wayne DB-9M DB-9M DB-9F DB 9 DB9(M) 3 2 5 5 54
TRIPORT AND ADAPTER CABLE Edacom 90 Note: Consult Factory Ecla Note: Consult Factory Fujitsu 9920 Note : Consult Factory Gasboy Cable : Cable Gas boy DB 9 (MALE) RJ 45 (FEMALE) RJ 45 DB9(M) 4 3 6 4 RJ 45 (MALE) Gilbarco PC G-site Cable: Gilbarco Triport DB 25 DB 9 (m) 55
TRIPORT AND ADAPTER CABLE DB 25 (F) DB9(M) 2 2 7 5 PC©G- Site Customer Display Unit Cable: (1) (2) (3) 1. RJ -45 2. Dual RJ-45 Jack 3.
TRIPORT AND ADAPTER CABLE Gilbarco TCR 15 Cable : Gilbarco Triport IBM 3151 Terminal DB 25 DB9(M) 2 2 7 5 Cable: Micromax triport DB 25 DB9(M) 3 2 5 7 MEM 5 Cable: Gilbarco Triport DB 25 (F) DB9(M) 2 2 7 5 57
TRIPORT AND ADAPTER CABLE Micrelec Note: consult Factory MicroPos Cable: Triport Micropos (1) (2) (3) 1. RJ -45 2. Dual RJ-45 Jack 3.
TRIPORT AND ADAPTER CABLE Micro, Local VSS Cable: Consult factory Micro IDN Network Cable: Micro IDN cable RJ 11 DB 9(M) 4 7 3 8 2 3 1 2 Micro ISN Network Cable: Micro ISN Cable RJ 11 DB9(M) 2 3 4 2 59
TRIPORT AND ADAPTER CABLE NCR 2113, 3000 cable: Consult factory Nixdof Beetle Cable: Consult factory Norand Cable: Cable Norand Tap DB 25 (F) DB9(M) 1 5 2 2 DB 25 DB9(M) 1 5 2 3 3 3 Emulator 60
TRIPORT AND ADAPTER CABLE Panasonic Cable: micromax cable DB 25 (F) DB9(M) 3 2 7 5 Pole Display Cable: PC Com 2 DB 25 (F) DB9(M) 2 2 7 5 61
TRIPORT AND ADAPTER CABLE Sharp 3110, 3100 DB 9 DB9(M) 5 5 2 2 Sharp 3220 DB 25 DB 9 2 2 3 3 7 5 4,5 6,8,20 62
TRIPORT AND ADAPTER CABLE Sharp A-460, A-470, A550, A-570, A610, A650 DB 9 (F) DB 9 (M) 2 3 3 2 5 5 7,6 1,4,8 SiaCom Cable : cable Siacom RJ 45 DB9(M) 7 2 3 3 Suntronic Cable: Consult factory Sweda Cable: Consult factory SwinTec Cable: Contract Factory 63
TRIPORT AND ADAPTER CABLE TCI Cable: Micromax DB 25 (F) DB9(M) 3 2 7 5 DB 25 (F) DB9(M) 3 2 7 5 Unitouch Cable : Consult Factory Verifone cable: Micromax, 64
TRIPORT AND ADAPTER CABLE Verifone cable: Micromax, RJ 45 DB 9 1 2 2 3 3 8 4 7 5 4 6 5 7 4 8 6 VSI DRS Cable: Contract factory 65
APPENDIX C Pinout For Standard Connectors 66
APPENDIX D PC BASED CASH REGISTERS There are myriad of PC based systems out there which do not appear on the AVE Cash Register Compatibility list. Most of PC base cash register that was not included in the AVE’s Cash Registers compatibility list can be able to interface to VSI-Pro. To find compatibility of cash register we need to determine following: If the Cash Register using a stand alone receipt printer. If YES then if it is a serial printer. If No then if it is a Parallel printer.
APPENDIX E HARD ALARM OUTPUT The VSI-Proprovides two open collector transistor alarm outputs to trigger alarming devices. These are Alarm 1 & 2 in the Alarm Menu. Upon an Exception, a VSI-Pro can be programmed to trigger a VCR to go to its fastest record time, have a Quad go full screen, home a switcher, trigger a preprogrammed PTZ, or provide visual or audible alarms. VSI-Pro provides two alaram output and VSI-Pro 16 provides 16 alarm outputs.
HARD ALARM OUTPUT 1 GROUND 14 GROUND 2 N/C 15 N/C 3 N/C 16 ALARM 1 (TTL COMPATIBLE) 4 ALARM 12 (TTL COMPATIBLE) 17 N/C 5 ALARM 15 ALARM 13 18 6 ALARM 14 19 ALARM 16 7 GROUND 20 ALARM 10 8 ALARM 9 21 ALARM 11 9 ALARM 8 22 ALARM 5 10 ALARM 7 23 ALARM 6 11 ALARM 4 24 ALARM 2 12 ALARM 3 25 3-12 VDC 13 3-12 VDC 1 6 2 7 3 8 4 9 5 ALARM 1 DSR RXD RTS TXD CTS DTR ALARM 2 GND DB9 (MALE) DB25 (MALE) VSI-PRO +16 DB 25 IN OUT VSI-PRO DB9 PINOUT 72
APPENDIX F MASTER RESET WARNING: DOING A MASTER RESET CLEARS ALL PROGRAMMING AND THE VSI-PRO DEFAULTS TO THE FACTORY SETTINGS If you have difficulty entering the Main Menu or you changed EPROMS in your VSI-Pro, do the following procedure exactly: With your left thumb lightly press and hold in the 3 buttons to the left (Up, Down & Set). While holding down these buttons, press and release the Reset button with your right thumb. Then release the other buttons.
LIMITED WARRANTY (Terms and Conditions) For 2 Years from the date of shipment, Seller warrants to Buyer that the Product is free from defects in material or workmanship under normal use and service. Equipment manufactured by other than Seller but furnished by Seller carries the same warranty to Buyer as Seller receives from the other manufacturer, notwithstanding any provision to the contrary.
BUYER’S EXCLUSIVE REMEDIES. If the Product supplied shall fail to conform to the contract or any applicable warranty, Buyer shall immediately notify Seller of such condition and afford Seller a reasonable opportunity to inspect said Product. Seller shall, at its option, either repair or replace such nonconforming Product.
DISPLAY ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF EX.
INDEX A DISPLAY 21 DISPLAY LINES 19 DOWN LOAD SETUP ALARM OUTPUT 36 ALARAM DURATION 38 ALARM NO.
INDEX M MAIN MENU 11 MASTER RESET 52, TRIGGER TEXT 39 TRUNCATE 19 75 U P PC BASE CASH REGISTER PINOUTS 67 PROBLEM SOLVING GUIDE P2RS 4 UPLOAD SETUP 71 W 50 WARRANTY R REGISTER DEMO REGISTER SELECT RS-232 4, 8 44 12 S SCREEN BLANK 18 SCREEN SETUP 14 BORDER GRAY SCALE 10, 14 CHARACTER SIZE 14 HORIZONTAL POSITION 10, 15 VERTICLE POSITION 10, 15 SCROLL DELAY 20 T TEST MODE 41 PORT 1 TEST 41 RX TEST 42 TX TEST 42 TEXT DISPLAY 18 TIME LAPSE VCR 4 TITLER ON SCREEN TITLE 17 TITLER 17 TRIGGER SWITCHER
NOTES 79
ASIA AVE (Thailand) Co., Ltd. 147 Soi On-Nuch 44 Sukhumvit 77 Rd. Suan Luang Bangkok 10250 Thailand Tel: 662-331-9364 Fax: 662-331-9365 Email: ave@avethailand.com http://www.ave.co.th (Thai) http://www.avethailand.com (English) NORTH AMERICA AVE USA 2000 West Governors Circle, Suite E Houston, Texas 77092 Tel: 281-443-2300 Fax: 281- 443-8915 Email: aveus@ave-us.com www.americanvideoequipment.