User manual
Installation and User Manual ADPRO FastTrace-R by Xtralis
86 Doc 13972_03
Select the type of audio input device connected to the FastTrace-R unit. Refer to Audio for details
of the hardware connector. Note that only one audio input type can be used, i.e. multiple audio
inputs cannot be used simultaneously.
Microphone Gain Operation
Options: AGC Enabled, AGC Disabled
Default: AGC Enabled
Select either AGC Enabled (Automatic Gain Control) or AGC Disabled. This option is only
activated when Microphone operation is selected under the Audio Input setting.
AGC is typically used in a more controlled noise environment, such as a Control Room or office,
where only a small amount of background noise is present.
Audio Input Gain
Options: Range 0 to 15
Factory Default: 2
Select a Gain level to apply to audio coming into the FastTrace-R unit (from local microphones).
Audio Out Volume
Options: Range 0 to 15
Factory Default: 2
Choose a volume level between 0 (lowest) and 15 (highest) to suit the operational environment.
4.3.16 Arming / Disarming
These option is not used in FastTrace-R.