User manual

Installation and User Manual ADPRO FastTrace-R by Xtralis
84 Doc 13972_03
Figure 83: Control Output Settings Menu
Control Output Settings
When the Configure button is used, the following settings can be made.
Control Output Name
Option: 16 characters maximum.
Enter the 16 character name to associate with this output. The name can be displayed when
viewing video from a camera input associated with this control output.
Default State
Option: Normally Open, Normally Closed
Default: Normally Open
Defines the state of the control output when it is not being driven by an alarm condition or
controlled remotely.
When set for ‘normally closed’, the control output is shorted to ground via the output transistor.
Manual Operation
The control outputs can either be operated by an operator at VideoCentral or linked to an alarm
condition. Select this box if the VideoCentral operator is to control the output.
Note that this option must be set to allow remote users access to the control output function.
Disconnect Operation
Option: Reset, Latch
Default: Reset