User manual
ADPRO FastTrace-R by Xtralis Installation and User Manual
Doc 13972_03 83
Figure 82: Presidium Input Settings
Presidium Input Name
Option: 16 characters maximum.
Enter the name to be associated with this Presidium Input.
Presidium Input Camera View Style
Factory Default: Live
Cannot be changed for FastTrace-R operation.
4.3.14 Control Outputs
The Control Outputs option defines a number of parameters about the type and operation of the
output circuits connected to the FastTrace-R. The outputs are ‘open collector’ transistor circuits
used to generate a control signal (upon activation of an alarm) to activate third-party equipment
at the remote site, for example a boom gate controller or a floodlight control device.
Select the control output number from the displayed list. The number of control outputs available
depends on the FastTrace-R Model number. The status of a control output is shown by a small
icon to the left of the channel number.
• A control output is free when the ‘empty’ icon is shown next to the number
•The Connect button is used to enable a control output. A green tick is shown and details
can be modified
• To temporarily disable the use of a control output, the Disconnect button is used and a red
cross is shown. For example, set Disconnect if maintenance is being performed on the unit
under control.