User manual

ADPRO FastTrace-R by Xtralis Installation and User Manual
Doc 13972_03 81
Alarm Input Type
Options: Normally Open (N/O), Normally Closed (N/C), N/O SEOL, N/C SEOL, N/O
DEOL, N/C DEOL
Default: Normally Open
The FastTrace-R can be programmed to trigger a recording event when the contacts associated
with a channel change state. This may be when:
a normally closed contact changes its state to open, or
a normally open contact changes to close
The alarm inputs may be supervised to detect tamper (attempting to override the alarm contacts
by a cut or short) with either a SEOL (Single End of Line) or a DEOL (Dual End of Line) wiring
hierarchy in conjunction with N/O or N/C sensor contacts.
Depending on the alarm wiring strategy, SEOL termination is used to detect either a short circuit
on a line or on an open circuit, while DEOL is used to detect both short and open circuit
conditions.
Hold Time
Options: When active, 2 sec, 5 sec, 10 sec, 30 sec, 60 sec.
Factory Default: 10 seconds
When there is a requirement that two (related) alarm inputs must be active before a recording
event is activated (known as double knock alarm activation), the Hold Time option sets the time
‘window’ for the second alarm input to occur. Event combinations are defined in the Operational
Behaviour section.
If the second alarm input is not activated within the Hold Time period, no recording event will be
generated. Choose the value most suited to the event activation requirement.
Camera View Style for the Triggered Alarm
Factory Default: Live
Cannot be changed for FastTrace-R operation.
4.3.13 Presidium Inputs
The Presidium Inputs option enables the configuration of video outputs from a Presidium
Intelligent Video System to the FastTrace-R video inputs.
Note: At least one Presidium Input must be configured. If there are no inputs configured,
the following Presidium system alarms will not work at the FastTrace-R:
- Presidium Operational
- Tamper alert
- Over Temperature
- Communication to Presidium Lost
- Communication to Presidium Resumed
- Presidium Fault
Note: When connecting a FastTrace-R to a Presidium, each FastTrace-R video input must
be directly connected to a Presidium video output. Hence, if the Presidium has 20
channels, a 20 channel FastTrace-R is required to operate all 20 channels.