User manual
ADPRO FastTrace-R by Xtralis Installation and User Manual
Doc 13972_03 73
To help configure the Activity Detection feature, the sensitivity to movement and the amount of
time that movement occurs can be programmed. This is done by selecting the Activity
Detection tab.
PTZ Settings
This Camera has a PTZ station.
Options: Yes, N o
Default: No
Set the checkbox when this channel is connected to a camera with PTZ (Pan/Tilt/Zoom). The
type of PTZ equipment is set in the PTZ Settings option (refer to PTZ Settings).
If checked, the Configure button will become available. By clicking on the Configure button, the
Alarm Preset Settings may be modified.
Figure 71: Camera Settings - PTZ
The PTZ Preset on Alarm feature allows the user to associate an alarm input, activity detection
on another connected camera or an ATM/EPOS transaction, to a preset camera position, so that,
in the event of an alarm, FastTrace-R will send the PTZ camera to a pre-programmed preset
position automatically.
The following parameters must be defined to use the PTZ preset on alarm feature:
• Alarm Preset Interrupt
• Time delay between Alarm Presets
• Enable Auto-Home
• Auto-Home expiry time
Alarm Preset Interrupt
Options: Interruptible, Non-Interruptible
Default: Interruptible
This option determines whether a PTZ camera that is currently going to a preset because of an
alarm activation, can be directed to another preset when another alarm activation occurs (or be
manually moved by an operator connected via a FastTrace-R comms or network port).
If set to Interruptible, when a camera is in the process of going to a preset (say preset 4), and
then another alarm occurs with an associated preset (say preset 5), the camera will terminate the
movement to preset 4 and go to preset 5. If the setting was Non-Interruptible, then the camera
would complete the movement and image acquisition at preset 4, and then go to preset 5.