User manual
ADPRO FastTrace-R by Xtralis Installation and User Manual
Doc 13972_03 57
Adjusting FastTrace-R Time via VideoCentral
If the time zone has been set correctly, as detailed above, but the time at the FastTrace-R is not
accurate, the time may be changed via VideoCentral.
This may be performed by double clicking on the time and date displayed at VideoCentral while
connected to the FastTrace-R. The following screen is displayed:
Figure 61: Set FastTrace-R Time and Date
When changing the time via the VideoCentral User Interface (by double clicking on the displayed
date and time), the software version installed at the FastTrace-R and VideoCentral will determine
the time change behaviour, as per the following table:
Table 11: Time Change Compatibility Matrix
Feature /
Scenario
VideoCentral V9.01
or later connecting
to
FastTrace-R V2.07
or later
VideoCentral V9.00
or later connecting
to
FastTrace-R V2.07
or later
VideoCentral prior
to V9.00
connecting to
FastTrace-R V2.07
or later
Large time
change
allowed
Yes No No
Small time
change
threshold
10 minutes 1 hour 60 seconds/1 hour
(see below)
User
attempts to
make a large
forward time
change
Message displayed
stating that time and
date have been
successfully
changed.
Message displayed
to user directing
them to the Installer
Menu (Setup GUI),
and indicating that
they may instead
wish to change the
time zone or
daylight savings
settings.
If the time change is
more than 60
seconds, an urgent
warning (red text) is
displayed indicating
that a gap will exist
in the recorded data.
If the user proceeds,
and the time change
is more than 1 hour,
FastTrace-R will
return an error code
and VideoCentral
will display an
"Unknown error"
message. If the time
change is less than
1 hour, the time
change will be made
gradually.