User manual
Installation and User Manual ADPRO FastTrace-R by Xtralis
50 Doc 13972_03
3.13 Powering Up the FastTrace-R
The FastTrace-R is supplied with a universal input power supply which operates from 100-240 V
AC, 50-60 Hz. There are no switches to change based upon your particular mains power voltage
or frequency.
When power is applied to the FastTrace-R the green LED located on the front panel of the unit
will illuminate.
If the green LED fails to illuminate check that there is power available from the socket into which
the FastTrace-R is connected.
The FastTrace-R will then automatically perform a series of self-test routines which check the
microprocessor circuits. When power is first applied to the FastTrace-R unit, the red LED on the
front of the unit will be on. After approximately 60 seconds, the red LED should start switching
on, then off, every two seconds. This signifies that the unit has completed its internal checks and
is now checking the integrity of the HDDs. Once the unit successfully completes the integrity
check, the red LED will switch off, and remain off.
If at any time during operation, the red LED switches on and stays on, this signifies a fault with
the unit and technical support is required.
If the red LED does not switch off and remain off, do the following:
1. Unplug all of the connectors except the power and re-power the unit.
2. If the red LED extinguishes, plug each connector back in and check that the red LED
remains off.
3. If the red LED does not extinguish after 10 minutes, please contact ADPRO technical
support.
If the red LED continues to flash for an extended period, this signifies that corruption has been
found with the database and the unit is attempting to correct the fault.