Doc 13972_03 49
3.12.3 Clock Synchronise - Pin 5
Currently unused.
3.12.4 Push to Talk - Pin 7
Currently unused.
3.12.5 Mode Select Input - Pin 9
The way a FastTrace-R operates its recording and alarm event recording features can be
changed by using up to four different operating modes. The parameters that define a particular
mode of operation, such as recording rate and alarm recording responses, are configured by
using the FastTrace-R Installer Menu.
From the FastTrace-R Installer Menu, any two (of the four) operating modes can be assigned to
activate depending on the open/closed state of the Mode Select input pin.
When the Mode Select pin is ‘open’ (orhigh’), the FastTrace-R operates by using the mode
parameters assigned to that pin state. Placing a closed contact’ on the pin switches the unit into
an alternate mode.
3.12.6 Fault Relay
FastTrace-R has a fault relay, which is a double pole type, i.e. complementary Normally Open/
Normally Closed poles, on pins 13, 14 and 15 of the General Inputs/Outputs connector. The Fault
relay activates while the FastTrace-R is in a fault state. The contacts will remain in the
changeover condition until reset.
The operation is as follows:
When the unit is powered off, the relay is Normally Closed.
When the unit powers up and is booting, i.e. the red light is on or flashing, the fault relay is
Normally Closed.
When the unit is operating normally, the fault relay will be Normally Open.
In the case of an over-temperature situation, the fault relay will be Normally Closed until the
temperature returns to normal.
Ratings: Switching Voltage = 30 VDC maximum
Switching Current = 1 Amp maximum
Isolation = 750 V maximum
3.12.7 General Alarm Relay Output
Pins 10, 11 and 12 contain a Form C single pole changeover contact set. If configured to do so,
the General Alarm relay activates while the FastTrace-R has an alarm recording event active.
The contacts will remain in the changeover condition until all alarms are reset.
Ratings: Switching Voltage = 30 VDC maximum
Switching Current = 1 Amp maximum
Isolation = 750 V maximum
The relay may also be configured to activate whenever the unit is connected via a network or
data link to the Remote Viewing Software (e.g. VideoCentral). This feature may be used (for
instance) to notify a third-party alarm system when FastTrace-R activity is taking place.