Figure 49: Typical PTZ Configuration
3.9.1 PTZ Port Setup
The following points are applicable to the PTZ port.
Telemetry stations are connected via a 9-pin D connector, marked ‘PTZ’
RS485 control links allow cable lengths of up to 1000 metres
Up to 20 (identical) telemetry stations can be connected to one FastTrace-R
Use the following guidelines when connecting and setting up a telemetry station.
The same brand and model of telemetry station must be used at a site if multiple units are to
be used.
Set the address of the telemetry station to match the camera input to which the PTZ camera
is connected.
Use shielded twisted pair cable for connection to the telemetry stations.
Connect the Transmit positive (TXD+ pin#2), Transmit negative (TXD- pin#3) and Ground
terminal (pin#5) of the FastTrace-R PTZ connector to the respective positive, negative and
ground terminals of the telemetry station as shown below.