Figure 43: Alarm Connector Pinouts
Wire connections from the alarm switches are made by using the screw terminal contact strips
supplied with the FastTrace-R. For ease of installation, the screw terminal blocks slide over the
connector pins when the wiring is complete.
Caution: DO NOT attempt to solder directly onto the connector pins, as this may cause heat
damage to the connector housing or to the interface PCB.
The setup options for alarm inputs are described with reference to the ‘rest’ or non-alarm position
of a set of switch contacts:
Normally Open - needs a closing alarm contact to activate an alarm
Normally Closed - needs an opening alarm contact to activate an alarm
SEOL Normally Open - Single End of Line termination with N/O contacts
SEOL Normally Closed - Single End of Line termination with N/C contacts
DEOL Normally Open - Dual End of Line termination with N/O contacts
DEOL Normally Closed - Dual End of Line termination with N/C contacts