38 Doc 13972_03
Table 7: DIP Switch Configuration
After changing any DIP switches the FastTrace-R must be repowered for the changes to take
effect.
The impound switch (DIP switch 6) will stop the system recording or deleting any data on the
disks. This can be used where a complete unit is required for evidential purposes (refer to
Section 6 - FastTrace-R Impounding).
Switch Function
1On
Off Factory Set
2 On Factory Set
Off
3On
Off Factory Set
4On
Off Factory Set
5 On RS422 Configuration for PTZ port
Off RS485 Configuration for PTZ port
6 On Impounded
Off Normal Operating Position
7 On Default override setting for direct connection
Note: Refer to FastTrace-R Connection Details Lost for
an explanation of this switch functionality.
Off Normal Operating Position
8 On PTZ RS485 Termination On
Off PTZ RS485 Termination Off
9 On GP Serial 2 is enabled for EPOS/ATM interfacing
Off Factory Set
10 On NTSC Video Standard
Off PAL Video Standard
11 N/A Leave both switches 11 and 12 in the ON position
12 N/A