User manual

Installation and User Manual ADPRO FastTrace-R by Xtralis
122 Doc 13972_03
Alarm inputs Model 5010: 20 alarm contact sensing or logic level inputs.
Model 5020: 30 alarm contact sensing or logic level inputs.
Programmable to trigger an alarm on contact opening or closure.
All inputs have impedance >1 K ohm and transient protection >20 KV.
Single End-of-Line (SEOL) or Dual End-of-Line (DEOL) tamper detection on each input.
Screw terminal connectors.
Voltage input less than 0.8 V = logic low, 7 mA (maximum).
Voltage input between 3.5 V and 5.0 V = logic high.
Minimum alarm contact duration = 100 milliseconds
Activity Detect Zones The maximum activity detection area is defined by the number of available detection
zones:
396 zones (22 wide x 18 high) using CIF PAL resolution (352 x 288 pixels)
330 zones (22 wide x 15 high) using CIF NTSC resolution (352 x 240 pixels)
A detection zone represents a screen area of 16 x 16 pixels.
Control outputs Model 5005 and Model 5010: 10 open collector outputs.
Model 5020: 20 open collector outputs.
Screw terminal connectors.
12 Vdc (maximum), 100mA (maximum)
‘On state’ output voltage less than 1.1 V @ 100 mA.
General Alarm Relay output Form C, single pole changeover. Relay contact ratings: 1.0 amp, 32 volts.
Network Port 1x Ethernet 10BaseT / 100BaseT compatible supporting TCP/IP. RJ-45 connector.
Serial Communication Interface 2x V.24 asynchronous interfaces - 8 data bits, 1 stop bit, no parity, programmable data
rate steps from 9600 to 230400 bps. 1x 9 pin male D, 1x 25-pin male D. Configured as a
DTE device.
Supports Hayes (AT) compatible ISDN and PSTN modems in dial or leased line
configuration.
Support for Multilink PPP or V.120 data protocol over ISDN.
GP Serial Ports 2x General Purpose (GP) serial RS-232 data ports for POS/ATM connection.
9 pin male D connectors. Configured as a DTE device. Maximum baud rate of 38,400
bps.
Programmable number of data bits (6, 7 or 8), stop bits (1 or 2), parity (odd, even,
none),).
Data (Transparent) Interface Bi-directional (transparent) RS-232 serial data link between the Transmitter and
Receiver.
Configured as a DTE device.
Programmable baud rate from 1200, 2400, 4800, 9600, 19200, 38400, and 57600 bps.
Programmable number of data bits (7 or 8), stop bits (1 or 2), parity (odd, even, none),
flow control via handshaking (or Off).
9 pin male D connector.
I/O Interface 1x ‘Mode Select’ input pin. Programmable control of mode numbers assigned to pin
state.
Available via 15-pin male D connector.
Function Description